6-12 General
Short Text
Long Text
Comments
Lightning Sensor
Fault*
No communication with lightning
sensor (local) OR
Lightning sensor fatal fault: [fault
codes]. Try cycling lightning sensor
power (global) OR
No lightning sensor data: [Heading
fault | GPS fault] (global)
Recommend cycling
power to the lightning
sensor. If the problem
persists, contact a local
dealer for service.
Lightning Sensor
Fault*
No communication with lightning
sensor (local) OR
No lightning sensor data: [Horz
antenna | Vert antenna | Sense
antenna | Sensor fault | Stuck mic |
Antenna config | Heading Fault |
GPS Fault] (global) OR
Lightning sensor recoverable fault:
[codes] (global)
If the problem persists,
contact a local dealer
for service.
Traffic Sensor Fault*
Traffic sensor failed to start self test
OR
Traffic sensor altitude unavailable
If the problem persists,
contact a local dealer
for service.
COM Stuck Mic
Stuck mic timeout, Release PTT
Displayed after
approximately 25
seconds of continuous
transmission.
<Application>
Function Lost
<Application> function is not
responding
Displayed if an
application (e.g.
Datalink, lightning
sensor, traffic, etc)
monitored by the IFD
stops reporting a status
message. If the
problem persists,
contact a local dealer
for service.
CrossSync Fault
Attempting to re-establish
CrossSync
Displayed when dual
IFDs have been
installed and
configured to share data
between the units but
there is no
communication between
the IFDs, or one IFD is
turned off. Contact the
Avidyne Service Center
or a local dealer for
service.